Part K guarding heights and the 100 mm sphere rule
Under Irish Building Regulations Technical Guidance Document K (2014), guarding is mandatory wherever a vertical drop or stair rise exceeds 600 mm. Minimum guarding height is 900 mm along private domestic stair flights and 1,100 mm on external balconies, roof terraces and external landings, with no opening wide enough for a 100 mm sphere.
Exact Irish Building Regulations TGD Part K (2014) dimensions for stair railings, external drops, raised terraces and balcony metalwork.
Free, no obligation. One local fabricator prices it, not five.
- > 600 mmdrop triggering Part K guarding
- 900 mmprivate stair flight guarding
- 1,100 mmexternal balcony & terrace height
- < 100 mmmaximum sphere gap between bars

Part K height thresholds by location
Internal private domestic stair flight
- Minimum height
- 900 mm
- Key Part K check
- Measured vertically from the pitch line connecting stair nosings.
External balcony, roof terrace or raised deck
- Minimum height
- 1,100 mm
- Key Part K check
- Measured vertically from finished walking surface including tiles or decking.
External steps & retaining wall drop > 600 mm
- Minimum height
- 1,100 mm
- Key Part K check
- 900–1,000 mm handrail along flight; 1,100 mm guarding on horizontal landings.
Common stairs or apartment balconies
- Minimum height
- 1,100 mm
- Key Part K check
- Heavier commercial horizontal crowd load applies alongside 100 mm gap limit.
Price my railings
Four quick taps and our price shows before we ask for a phone number. One local fabricator rings you, not five.
Balcony metal railings, about 6 m (4 m to 8 m), fitted to steps, a ramp or a balcony: €1,260 to €2,160, supplied and fitted.
How the price is worked out
The range reflects typical supply-and-fit metal railing prices in Ireland for hot-dip galvanised and polyester powder-coated steel (or Grade 316 stainless on coastal jobs). Short runs under 4 m reflect a workshop minimum charge covering site measuring, welding, dipping and fitting. Core-drilling into granite coping, raking panels to match steep slopes, removing rusted ironwork and matching pedestrian gates are priced after an on-site measure. Ask whether VAT is quoted at 13.5% or 23%. Use this figure to plan: only a fabricator who measures your wall or steps gives a firm written quote.
The 100 mm sphere test and non-climbable bar layout
Two child-safety rules sit right beside height inside TGD Part K and catch out many imported kit railings ordered without Irish engineering checks.
- No 100 mm sphere may pass through any gap. That applies between vertical pickets, at the end post beside a house wall, and underneath the bottom horizontal bar above a step or balcony slab.
- Non-climbable design for under-fives. Anywhere children under five have access, railings must avoid horizontal rungs or decorative scrolls that act like ladder steps.
- Measure from finished floor, not concrete sub-base. Raising a balcony floor by 80 mm with timber joists or paving pedestals after railings are fitted drops an 1,100 mm rail to an illegal 1,020 mm.
- Structural horizontal loading (0.74 kN/m). Domestic balcony railings must withstand sustained leaning pressure without flexing loose at the post bases.
Related metal railing guides
Balcony metal railings1,100 mm Part K vertical steel balcony guarding and waterproof fixings.
Exterior step handrailsOutdoor concrete and stone step handrails, mobility rails and council grants.
Regulations & planningClass 5 front wall 1.2 m cap, TGD Part K rules and Section 5 checks.
Core-drilling vs baseplatesHow railing posts fix cleanly into coping stones, concrete steps and soil.
Modern flat-bar railingsArchitectural vertical flat-bar and box-section railings in black or grey.
Railings cost per metreComplete Irish supply-and-fit price guide per metre plus site extras.Questions homeowners ask before ordering
What drop height requires a railing by law in Ireland?
Under TGD Part K (2014), any open edge of a floor, landing, ramp, balcony or raised terrace with a drop over 600 mm requires compliant safety guarding.
Can I use 900 mm railings on a raised back patio with an 800 mm drop?
No. Because the external drop exceeds 600 mm, external horizontal edge guarding must reach 1,100 mm under Part K.
What picket spacing satisfies the 100 mm sphere rule?
Fabricators usually space 12 mm to 16 mm vertical bars at 105 mm to 110 mm centres, leaving an actual clear gap of roughly 90 mm to 95 mm so a 100 mm sphere cannot squeeze through.
Are horizontal steel wires or bars banned on Irish balconies?
Horizontal wires or rails can be climbed easily by toddlers and generally fail Part K climbability requirements on domestic balconies unless a solid infill or vertical pickets prevent footholds.